PIAB 9:300B Electronic Unit

The PIAB 9:300B Electronic unit is mainly used together with one load cell / force transmitter in order to protect a lifting device against overload. It can also be used for other applications such as load indication. The PIAB 9:300B is very easy to install with screw terminal blocks and a back lit display. The unit is delivered programmed and adjusted to your required parameters from factory.


electronic_unit1.jpg electronic_unit2.jpg electronic_unit3.jpg

 

PIAB 9:300B function:
The PIAB 9:300B can be used for connection to PIAB force transmitters and / or PIAB load cells (0 – 2mV/V). The signal from the force transmitter is processed and amplified by the programmable circuit board (PCB) of the electronic unit.The PIAB 9:300B has two relays and one analogue 4 – 20 mA signal output:

 

Relay 1
Limit 1 is used for warning or slack rope control.

 

Relay 2
Limit 2 is used for overload limitation and includes two set points: 2A and 2B. 2A has a possibility to set on- and off delay of the overload limit. 2B is used for a value that is greater than 2A and has no delay function.

 

4 – 20 mA:
The analogue signal output can be used to transfer the load indication to your own system or to run a PIAB MICROBUS large format display.

 

PIAB 9:300B safety:

The PIAB 9:300B Electronic Unit is self-checking. Any malfunction of load cell or cable will indicate overload. This informs the operator that the system is out of order.

  • Transducer input: 
    0 - 2 mV/V.
  • Operating voltage:
    110 or 240 VAC.
  • Working Temperature:
    -20 to +70°C.
  • Protection class:
    IP 65 according to IEC 529 / NEMA 13.
  • Switch Off Capacity:
    8 A, 250 V AC
  • Is designed for use in aggressive industrial environment. The individual printed circuit boards are mounted on chock absorbing devices. The electronic is mounted into a lockable steel box (protection class IP 65).
  • The PIAB Electronic Units are self checking. Malfunction of system components (transducer, amplifier or cable) will indicate overload.
  • All connections are made to terminal blocks -Earth connections (ground) for power supply and signals are separated (to avoid interference).